400 Hz AC LIGHT LOAD BANK – DIGITAL USB ALB-L-80DU

Advantages

  • Simple operation suitable for non-trained operators and personnel; no maintenance required
  • Suitable for workshop or airside operation; silent unit rated at < 70 dB(A) at 7m / 23Ft
  • Luggage type casing with pull up handle as standard for every lightweight load bank
  • Cant protection – load bank works only when positioned on flat horizontal surface
  • Digital load banks do not require any further calibration process once delivered
  • Free DEKAL licensed software application and proper drivers included
  • All measurements possible to archive and printout, including diagram graphics
  • In accordance & fully complied with AFI 33-115 volume 2, Certified by: SAF/A6C
  • 400 Hz AC 6-Pole receptacle in accordance with NATO & MIL-C-81790 specification
  • Fine load regulation knob as standard for complete series of 400 Hz AC load banks
  • Housing made of non-corrosive parts with component quality control by the manufacturer
  • High reliability with multiple thermal protection – extremely resistant to high temperature
  • Extra safety and isolated jack sockets for connecting external voltage measuring device
  • Short worldwide delivery period with tracking feature and insurance for all products
  • Spare parts availability and accurate on-time deliveries by appointed courier
  • 2 years full warranty with extension option for all DEKAL load banks
  • CE certification – health, safety, and environmental protection standards
  • Made for GPU’s testing procedure according to ISO 6858, DFS 400, ARP 5015
  • Classification CE marking, DIN, VDE, IEC, IP 21 protection rate level
  • Customs classification Harmonized System tariff code HS: 8516808000
SKU: ALB-L-80DU Category:

400 Hz AC LIGHT LOAD BANK – DIGITAL USB ALB-L-80DU

TECHNICAL SPECIFICATION ALB-L-80DU
VOLTAGE [V] * FREQUENCY [Hz] 115 / 200 V AC ± 10 % * 400 Hz ± 10 %
LOAD / POWER [kW / kVA cosφ=1] 0 – 80 kW ± 5 %
FINE ADJUSTMENT – POTENTIOMETER 0 – 8 kW
RATE SWITCH REG. LOAD STEPS ± 5%
ROUGH ADJUSTMENTS – 8 kW STEPS
POWER [kW / kVA cosφ=1]
9 SEQUENCE STEPS:
8 – 16 kW
16 – 24 kW
24 – 32 kW
32 – 40 kW
40 – 48 kW
48 – 56 kW
56 – 64 kW
64 – 72 kW
72 – 80 kW
FORCED AIR COOLING [m³/min & CFM] 88.20 m³/min – 3120 CFM
MEASUREMENTS & INDICATIONS
DIGITAL POWER METER PARAMETERS 3 LINE HIGH BRIGHTNESS RED LED DISPLAY CLASS: ±0.5 % ; S ACC. IEC 62053-22:2003;
DISPLAYED: V / A / Hz / cosφ=1 / kW / kVA;
USB INTERFACE SPECIFICATIONS USB PLUG IN CONNECTION FOR DATA PRINTOUT
ARCHIVE, INCLUDING FREE DEKAL LICENSED SOFTWARE & USB CABLE
LIGHT INDICATION PHASE INDICATION, PHASE ROTATION, INTERLOCK CIRCUIT
GPU TESTING PROCEDURE* *Proposal procedure:
LOAD raising from 0 → 100% ? 30 seconds;
HOLD at 100% ? 5 minutes;
LOAD decrease from 100 → 0% ? 10 minutes
ENGINE DECARBONISING* *Proposal procedure:
LOAD raising from 0 → 100% ? 30 seconds;
HOLD at 100% ? 45 minutes;
LOAD decrease from 100 → 0% ? 15 minutes
DIMENSIONS & WEIGHT
LOAD BANK SIZE [L x W x H] mm / Kg 510 x 210 x 450 / 26
LOAD BANK SIZE [L x W x H] In / Lbs 20 x 8.3 x 17.7 / 57
TRANSPORT CASING [L x W x H] mm / Kg 630 x 600 x 330 / 9
TRANSPORT CASING [L x W x H] In / Lbs 24.8 x 23.6 x 13 / 19
LOAD BANK PAINTING / TRANSPORT CASING FINE POWDER COATING STRUCTURE DRYLAC® 29_80081
LIGHTWEIGHT LUGGAGE TYPE CASING WITH PULP UP HANDLE