CABLE / PLUG TEST BOX 28.5 V DC – ALB-140D + EP20

Advantages

Specifically designed rugged units used for the testing and servicing 115/200 v 400 hz power cables & aircraft plugs.

Indications

  • Phase presence A – B – C
  • Phase direction right or left
  • E&f interlock & test

Measurements:

  • External measuring device option (digital voltmeter/multimeter)
SKU: ALB-140D-EP20 Category:

CABLE / PLUG TEST BOX 28.5 V DC – ALB-140D + EP20

TECHNICAL SPECIFICATION
ALB-140D + EP20
VOLTAGE [V] 115 /200 V AC ± 10 %
FREQUENCY [Hz] 400 Hz ± 10 %
LOAD / POWER [kW / kVA] [cosφ=1] 144 kW ± 10 %
3 LINE HIGH BRIGHTNESS RED LED DISPLAY CLASS : ±0.5% S ACC. IEC 62053-22 2003 V / A / Hz / cosφ=1 / kW / kVA
 
CONNECTION TO PC ( LAN CABLE & SOFTWARE INCL.) LAN+USB+WiFi
LOAD TEST PROPOSAL FOR GPU TESTING
 
LOAD raising within 30 sec. from 0 to 100% LOAD, HOLD on 100% LOAD for 5 min LOAD decreasing within 10 min from 100 to 0% LOAD
LOAD TEST PROPOSAL FOR ENGINE DECARBONISING
 
LOAD raising within 30 sec. from 0 to 100% LOAD, HOLD on 100% LOAD for 45 min LOAD decreasing within 15 min from 100 to 0% LOAD
COOLING – FORCED [m³/min] 88,20
EP10 or EP20 OPTION
ADDITIONAL EXTERNAL POWER SUPPLY EP-10 110 V AC / 60 Hz ± 20 %
ADDITIONAL EXTERNAL POWER SUPPLY EP-20 230 V AC / 50 Hz ± 20 %
MAINS CABLE INCL. 2,5 m
ADDITIONAL EXTERNAL POWER SUPPLY EP-20 < 20 ms
NORMS
STANDARDS ISO 6858, DSF 400, ARP 5015
CLASIFICATION CE marking, DIN, VDE, IEC
ENVIROMENT
OPERATING TEMPERATURE -20 ºC to 55 ºC
MAXIMUM ALTITUDE 1000 m (w/o Downgrading), max.2000m
RELATIVE HUMIDITY 0% – 85% (w/o Condensation)
DEGREE OF PROTECTION IP 21
DIMENSIONS [L x B x H] / [kg] 630 x 230 x 630 / 40
PAINTING POWDER COATING FINE STRUCTURE 71319 IGP / Swiss quality

Available models: