28.5 V DC LIGHT DIGITAL USB LOAD BANK – DLB-L-ESS-20DU

Advantages

  • Simple operation suitable for non-trained operators and personnel; no maintenance required
  • Suitable for workshop or airside operation; silent unit rated at < 70 dB(A) at 7m / 23Ft
  • Environmental operating temperature from -20 ºC to 55 ºC / -4 ºF to 122 ºF
  • Cant protection – load bank works only when positioned on flat horizontal surface
  • Phase detection and rotation indicator – ABC availability, sequence of three-phase voltage
  • Fine load regulation knob as standard for complete series of 400 Hz AC load banks
  • 400 Hz 6-Pole receptacle in accordance with NATO & MIL-C-81790 specification
  • Equipped with 28 V DC control circuit for E&F and applicable bypass interlock circuit
  • Housing made of non-corrosive parts with component quality control by the manufacturer
  • High reliability with multiple thermal protection – extremely resistant to high temperature
  • Extra safety and isolated jack sockets for connecting external voltage measuring device
  • Short worldwide delivery period with tracking feature and insurance for all products
  • Spare parts availability and accurate on-time deliveries by appointed courier
  • Transport casing with pull up handle as standard for every load bank manufactured
  • 2 years full warranty with extension option for all DEKAL load banks
  • CE certification – health, safety, and environmental protection standards
  • Made for GPU’s testing procedure according to ISO 6858, DFS 400, ARP 5015
  • Classification CE marking, DIN, VDE, IEC, IP 21 protection rate level
  • Customs classification Harmonized System tariff code HS: 8516808000
SKU: DLB-L-ESS-20DU Category:

28.5 V DC LIGHT DIGITAL USB LOAD BANK – DLB-L-ESS-20DU

TECHNICAL SPECIFICATION DLB-ESS-L-20DU
VOLTAGE [V] 28.5 V DC ± 10 %
LOAD REGIME OPTIONS [A]

 

300 A OR 600 A CONTINUOUS &
2000 A ± 20 % ESS PROCEDURE
LOAD TEST PROCEDURE TYPE

 

AIRCRAFT ENGINE START SIMULATION (ESS)

in duration of 35 seconds DECREASING

LOAD TEST SPECIFICATION AT 28.5 V DC
[CONTINUOUS & DECREASING]

 

SEQUENCE OF 6 STEPS
ENGINE START SIMULATION
Step 1: 2000 A for 1 second
Step 2: 1700 A for 3 seconds
Step 3: 1200 A for 10 seconds
Step 4: 1000 A for 20 seconds
Step 5: 700 A for 30 seconds
Step 6: 400 A for 35 seconds
LOAD TEST SPECIFICATION AT 28.5 V DC
[CONTINUOUS – SELECTED MANUALLY]
300 A CONTINUOUS LOAD
600 A CONTINUOUS LOAD
[DECREASING ESS – SELECTED MANUALLY] 2000 A DECREASING ESS
FORCED AIR COOLING [m3/min & CFM] 44.10 m3/min – 1560 CFM
MEASUREMENTS & INDICATIONS
DIGITAL POWER METER PARAMETERS

 

3 LINE HIGH BRIGHTNESS RED LED DISPLAY CLASS: ±0.5 % FS + 2C;

DISPLAYED: V / A / kW

USB INTERFACE SPECIFICATIONS

 

USB PLUG IN CONNECTION FOR DATA PRINTOUT/ARCHIVE,

INCLUDING FREE DEKAL LICENSED SOFTWARE & USB CABLE

LIGHT INDICATION 28 V DC POWER INDICATION, FAILURE INDICATOR
GPU TESTING PROCEDURE
AND ENGINE DECARBONISING*
*LOAD 300 A or 600 A ? 30 / 15 minutes
ESS in 6 STEPS 100% → 0% ? 35 seconds
OPERATING TEMPERATURE [°C / °F] from -20 °C to 55 °C / from -4 °F to 122 °F
NOISE LEVEL [dB] AT DISTANCE [m/Ft] < 70 dB(A) at the distance of 7m / 23Ft
DIMENSIONS & WEIGHT
LOAD BANK SIZE [L x W x H] mm / Kg 530 x 210 x 310 / 24
LOAD BANK SIZE [L x W x H] In / Lbs 20.8 x 8.3 x 12.2 / 52
TRANSPORT CASING [L x W x H] mm / Kg 680 x 520 x 380 / 17
TRANSPORT CASING [L x W x H] In / Lbs 26.6 x 20.6 x 14.8 / 15.7
LOAD BANK PAINTING / TRANSPORT CASING

 

FINE POWDER COATING STRUCTURE DRYLAC® 29_80081
ALUMINIUM FRAME WITH BLACK LAMINATED PLYWOOD PANEL